![]() PDF VersionsErrata for viewLinc 3.4.100.533 Errata for viewLinc 3.4.6.2968 Errata
for viewLinc 3.4.6.2963 Errata
for viewLinc 3.4.5.2911 Errata for
viewLinc 3.4.4.2869 Errata for viewLinc
3.4.3.1823 Errata
for viewLinc 3.4.3.1804 Errata for
viewLinc 3.4.1.1703 |
Errata for viewLinc™viewLinc version 3.4.100.533Issued April 26, 2010 General:- To ensure data timestamp accuracy, verify that the viewLinc server time is set accurately before installing the viewLinc software. The viewLinc server and logger host should also be set to have its time synchronized with an accurate source once a day at a minimum. Alarms:- Ensure that the delay for Calibration Alarms is set to 0. This is to prevent artificial ballooning of the historical database. System: - On large systems (1000 or more channels) timing parameters in the configuration file may need to be modified to ensure optimum performance. Please see the readme file or contact Technical Support for more information if you are using a system of this size. Reporting:- When a manual report is started during a time when scheduled reports are running or other users are generatingreports, the status of the manually generated report is listed as “Queued”. The status will remain “Queued” until the queue gets to this report. This could be a significant period of time depending on the size and quantity of reports already in the queue. - Due to the time required to generate reports, it is recommended that scheduled reports be set up to start during nonpeak times and have at least 15 minutes between each report. This will reduce the chance of a scheduled report delaying a manually requested report. It is also best not to schedule reports with large data sets to start at the same time. - For reports based on a fixed period in the past, alarm duration may be calculated incorrectly, if alarm deactivation was not covered by the report time range. The workaround for this is to try to extend report time range to include the entire lifespan of the alarm. Logger Swapping:- When swapping loggers it is important to allow the new Logger to come to equilibrium before placing it on the COM port. This will ensure that data recorded from outside of the environment is not included on reports. Real-Time Display:- In Channel View, vertical axis sometimes shows values formatted incorrectly (e.g. 10.10 instead of 11.0). There is currently no workaround for this. For more information and updates on viewLinc, contact Veriteq technical support. | |


Products & Services